Self recovery fuse selection method_tage electronic-Professional production of TVS tube, self recovery fuse, patch fuses manufacturer
在线客服
热线电话

微信公众账号
Hello! Welcome to Shenzhen Tergy Technology Co., Ltd.
全国服务热线
They are in search:Fuse | ESD protector | TVS diode | varistor | gravitron | MLCV | self recovery fuse
Support
Search
   Product Category Search
Latest applications
Contact Us
 
Company Name: Shenzhen Tage Technology Co., Ltd.
Phone: 86-755-88365418,88365225,88363209
Fax: 86-755-88361758 Holiday Service Phone: 18128869501 E-mail: evan@wwwhj7778.com
Address: Shenzhen Baoan District city streets of entrepreneurship garden Amoy king business building

Support

You are here:Home >> Support >> Support
Self recovery fuse selection method
Publish:Shenzhen Tergy Technology Co., Ltd.  Time:2016-08-01
1, determine the parameters of the circuit:
A maximum operating ambient temperature B standard operating current C maximum working voltage (Umax) d maximum fault current (Imax)
2, the principle of self recovery fuse
Self recovery fuse is made by special process of high tech polymer resin and nano conductive grains.
With the resin based conductive path forming a chain link, fuse the normal work; when the circuit short-circuit or overload, large current flows through the fuse set temperature, when the temperature reaches Curie, its density decreases rapidly, phase transition increases, a conductive link inside the avalanche state change or break, a fuse step - moved to the high impedance state current is quickly pinch off, thus to circuit fast, accurate limit and protect the small current of the fuse has been in a state of protection, when power failure and fault exclusion, the set temperature decreased, the density of States increases, phase recovery, nano crystal reduction into a chain of conductive path, since the recovery fuse returned to normal, without manual change.
自恢复保险丝选型方法
3, the maximum electrical rating of the selected components and the maximum operating voltage of the circuit and the fault current for comparison
Use the electrical characteristics table to verify the maximum operating voltage and fault current of the device you selected in the second step. Maximum operating voltage and maximum fault current of the device. Make sure that Umax and Imax are greater than or equal to the maximum operating voltage and maximum fault current of the circuit.
4, according to the maximum operating temperature of the circuit and the circuit, the control self recovery fuse temperature reduction rate to choose the appropriate product specifications to maintain the current
5, verify the working temperature of the environment
Ensure that the minimum and maximum ambient temperature of the application is within the operating temperature range of the self recovery fuse element. Most of the operating temperature ranges from -40 to 85.
6 control specifications provided by the data, confirm the specifications of the thermistor size to meet the requirements.
Products
江苏福彩网 辽宁福彩网 江苏福彩网 辽宁福彩网 上海福彩网 湖南福彩网 西藏福彩网 江苏福彩网 辽宁福彩网 江苏福彩网